Data set 01
1938 Raytheon
Published operating points and test conditions from this source.
Triode
Other
Plate Voltage Eb: e 100 100
165 V
Plate Voltage Eb: e 100 100 165 Vde
Grid #1 Circuit Resistance Rg/g: —eae PR 1.0
1.1 Meg
Grid #1 Circuit Resistance Rg/g: —eae PR 1.0 1.1 Meg.
Heater -Cathode Voltage Ehk: =200 cae- 100
200 V
Heater -Cathode Voltage Ehk: =200 cae- 100 +200 Vdc
be vibrated in each of the three planes for 30 minutes at a fixed frequency between 50 and
60 Hz
The tube shall then be vibrated in each of the three planes for 30 minutes at a fixed frequency between 50 and 60cps
for Vibration (1) and 450 and
500 Hz
for Vibration (1) and 450 and 500cps for Vibration (2). The same tubes shall be used for both vibration tests.