Skip to main content

Voltage Radio Detector Converter ·Hexode

CH1

Hexode frequency-changing valve for early superheterodyne receivers, intended for mixer/modulator service with an external oscillator. High output resistance supports useful isolation in all-current series-heater radios.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
P8A
Base pins
8
Nominal heater
13 V / 200 mA

Description

The Telefunken CH1 is treated as a frequency-changer hexode from the supplied C-series catalog context; the excerpt does not preserve a complete CH1 data row.

Socket description

European 8-pin side-contact base

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
P8A
Base pins
8
Nominal heater voltage
13 V
Nominal heater current
200 mA
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Hexode

X-ray radiationInterelectrode capacitances
Plate resistance
2000000 Ω
Transconductance
0.00055 S
Max plate voltage
250 V
Max screen voltage
125 V
Max plate dissipation
1.5 W
Max screen dissipation
0.5 W
Max cathode current
10 mA

Hexode; canonical SectionType list has no Hexode value, so Other is used.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1938 Philips Miniwatt Vacuum Tube Catalog

Published operating points and test conditions from this source.

SECTION 1

Hexode

Other

  • Plate voltage

    200 V

    Published table operating point

  • Control-grid bias

    2 V

    Published table operating point

  • Screen voltage

    100 V

    Published table operating point

  • Screen current

    4 mA

    Published table operating point

Characteristic

  • Transconductance

    2000000 µS

    Published table characteristic

  • Plate resistance

    200000 ohm

    Published table characteristic

  • Heater/filament voltage

    13 V

    Published heater/filament rating

  • Heater/filament current

    200 mA

    Published heater/filament rating

Capacitance

  • Grid-to-plate capacitance

    0.003 pF

    Published table capacitance

Data set 02

195X Tunsgram

Published operating points and test conditions from this source.

SECTION 1

Hexode

Other

  • Typical plate voltage

    250 V

  • Typical combined grid-2/grid-4 voltage

    80 V

  • Oscillator grid-3 voltage

    9 V

    RMS

  • Maximum no-current anode voltage

    550 V

  • Maximum grid-2/grid-4 no-current voltage

    400 V

  • Maximum heater-cathode voltage

    125 V

Data set 03

1999 Philips 0-D

Published operating points and test conditions from this source.

SECTION 1

Hexode

Characteristic

  • Conversion transconductance

    550 µS

    Modulator

  • Maximum transconductance

    2600 µS

    HFIFAmplifier