Data set 01
1999 Philips 0-D
Published operating points and test conditions from this source.
Pentode
Other
Typical plate current
40 mA
Va=200V
Typical screen current
9 mA
Vg2=100V
Output power
3.8 W
ClassA
Power - Pentode (NOT beam) ·Diode-Diode-Pentode
Philips double-diode output-pentode combination tube. Two detector/control diodes share the envelope with a power pentode, integrating receiver detection functions and audio output.
CBL6 is a double-diode output pentode. The supplied Philips datasheet was read for heater data, operating characteristics, limiting ratings, and section-level electrical information.
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
3 physical sections, each with unique specifications.
Section 1
Double-diode output pentode
Section 2
Double-diode output pentode
Section 3
No fixed ratings are recorded for this section.
Second physical diode section; added to complete Diode + Pentode + Diode structure and align with SectionCount 3.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Typical plate current
40 mA
Va=200V
Typical screen current
9 mA
Vg2=100V
Output power
3.8 W
ClassA