Data set 01
1955 Marconi
Published operating points and test conditions from this source.
Triode
Characteristic
Filament Voltage
7.2 V
Filament Current
170 A
Amplification Factor
26
Transconductance
19000 uS
Other
Maximum Anode Voltage
12000 V
Maximum Anode Dissipation
24000 W
Maximum Grid Dissipation
1000 W
Maximum/Peak Cathode Current
35 A
Frequency at Full Ratings
50 MHz
Capacitance
Anode-Grid Capacitance
30 pF
Anode-Cathode Capacitance
1.5 pF
Grid-Cathode Capacitance
46.5 pF
Construction
Cooling
Water plus seal air