Skip to main content

Power - Triode (over 1000V 100W) ·Triode

BR189

High-power forced-air-cooled RF transmitting triode arranged for cathode-driven operation. Its 27 kW plate dissipation and 12 kV rating support major grounded-grid communications and broadcast power stages.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
9 V / 240 A

Description

R.f. transmitting triode with grid terminals suitable for cathode-drive operation.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
9 V
Nominal heater current
240 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Transconductance
0.0275 S
Amplification factor
34
Max plate voltage
12000 V
Max plate dissipation
27000 W
Max grid dissipation
1250 W
Max cathode current
70 A

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1955 Marconi

Published operating points and test conditions from this source.

SECTION 1

Triode

Characteristic

  • Filament Voltage

    9 V

  • Filament Current

    240 A

  • Amplification Factor

    34

  • Transconductance

    27500 uS

Other

  • Maximum Anode Voltage

    12000 V

  • Maximum Anode Dissipation

    27000 W

  • Maximum Grid Dissipation

    1250 W

  • Maximum/Peak Cathode Current

    70 A

  • Frequency at Full Ratings

    50 MHz

Capacitance

  • Anode-Grid Capacitance

    51 pF

  • Anode-Cathode Capacitance

    1.5 pF

  • Grid-Cathode Capacitance

    68 pF

Construction

  • Cooling

    Forced air

Data set 02

1971 English Electric Valve

Published operating points and test conditions from this source.

SECTION 1

Triode

Other

  • Anode dissipation BR189

    27 kW

    BR189

  • Output power class C telegraphy

    30 kW

    ClassC