Skip to main content

Power - Triode (over 1000V 100W) ·Triode

BR179

Forced-air-cooled Marconi transmitting triode for HF and VHF power service. With 8 kW plate dissipation and full ratings to about 100 MHz, it suits substantial communications and broadcast-frequency amplification.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
6.6 V / 90 A

Description

Forced-air-cooled transmitting triode for HF/VHF power service.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
6.6 V
Nominal heater current
90 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Transconductance
0.01 S
Amplification factor
28
Max plate voltage
8500 V
Max plate dissipation
8000 W
Max grid dissipation
600 W
Max cathode current
16 A

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1955 Marconi

Published operating points and test conditions from this source.

SECTION 1

Triode

Characteristic

  • Filament Voltage

    6.6 V

  • Filament Current

    90 A

  • Amplification Factor

    28

  • Transconductance

    10000 uS

Other

  • Maximum Anode Voltage

    8500 V

  • Maximum Anode Dissipation

    8000 W

  • Maximum Grid Dissipation

    600 W

  • Maximum/Peak Cathode Current

    16 A

  • Frequency at Full Ratings

    100 MHz

Capacitance

  • Anode-Grid Capacitance

    32 pF

  • Anode-Cathode Capacitance

    1 pF

  • Grid-Cathode Capacitance

    33 pF

Construction

  • Cooling

    Forced air