Skip to main content

Power - Triode (over 1000V 100W) ·Triode

BR154

Industrial transmitting power triode intended for RF amplification, oscillation, or modulation. Manufacturer data emphasize substantial plate power, professional transmitter operation, and construction suited to continuous high-power service.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
3.3 V / 11.5 A

Description

The Marconi BR154 is a indirectly heated forced-air-cooled transmitting triode for grounded-grid vhf amplification.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
3.3 V
Nominal heater current
11.5 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Amplification factor
25
Max plate voltage
1500 V
Max plate dissipation
250 W

Highest published service maximums promoted; cooling and operating conditions preserved in parameters.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1955 Marconi

Published operating points and test conditions from this source.

SECTION 1

Triode

Other

  • Heater/filament voltage

    3.3 V

  • Heater/filament current

    11.5 A

  • Maximum plate voltage

    1500 V

  • Maximum plate dissipation

    250 W

  • Maximum frequency at full ratings

    220 MHz

  • Minimum cathode heating time

    2 min

  • Typical grounded-cathode plate voltage

    1500 V

  • Typical grounded-cathode output power

    290 W

  • Typical grounded-grid output power

    325 W

Characteristic

  • Amplification factor

    25

Capacitance

  • Grid-plate capacitance

    10.3 pF

  • Plate-cathode capacitance

    0.5 pF

  • Grid-cathode capacitance

    2.6 pF

Construction

  • Cooling

    Forced air