Data set 01
9999 Mixed I 1000
Published operating points and test conditions from this source.
Triode
Other
Plate Voltage
10000 V
RF transmitting triode typical operating point
Plate Current
26000 mA
RF transmitting triode typical operating point
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
Forced-air-cooled RF transmitting power triode. Maximum anode voltage 14 kV, maximum anode dissipation 36 kW; filament current 185 A; surge filament current 300 A maximum; peak usable cathode current 60 A; μ 90, gm 60 mA/V at specified operating points. Capacitances: grid-anode 75 pF, grid-filament 130 pF, anode-filament 1.0 pF.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Plate Voltage
10000 V
RF transmitting triode typical operating point
Plate Current
26000 mA
RF transmitting triode typical operating point