Skip to main content

Power - Triode ·Triode

BR1161

No short description is recorded for this tube.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
-

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
-
Nominal heater current
-
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Transconductance
0.06 S
Amplification factor
90
Max plate dissipation
36000 W

Forced-air-cooled RF transmitting power triode. Maximum anode voltage 14 kV, maximum anode dissipation 36 kW; filament current 185 A; surge filament current 300 A maximum; peak usable cathode current 60 A; μ 90, gm 60 mA/V at specified operating points. Capacitances: grid-anode 75 pF, grid-filament 130 pF, anode-filament 1.0 pF.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

9999 Mixed I 1000

Published operating points and test conditions from this source.

SECTION 1

Triode

Other

  • Plate Voltage

    10000 V

    RF transmitting triode typical operating point

  • Plate Current

    26000 mA