Skip to main content

Nixie ·Nixie

B7037

Gas-filled cold-cathode Nixie numerical indicator designed to display decimal digits by selective glow discharge of shaped cathodes.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
17-35
Socket code
SK137
Base pins
-
Nominal heater
-

Description

B7037 is a cold-cathode numeric or character indicator tube listed in the supplied German comparison catalog as comparable to RFT type Z5680M. The catalog provides electrical and mechanical data for that RFT type, including anode striking, maintaining, and operating limits. The source cautions that comparable types are not necessarily electrically identical, so the mapped RFT values are retained as comparison data rather than asserted as exact original-manufacturer ratings.

Socket description

SK-137 / RTS-5 17-contact large Nixie socket family

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
17-35
Socket code
SK137
Base pins
-
Nominal heater voltage
-
Nominal heater current
-
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

17-35 - Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Nixie

X-ray radiationInterelectrode capacitances
Max cathode current
7.5 mA
Regulator starting voltage
150 V
Regulator maintaining voltage
140 V

Special-purpose display/switching section. Published non-promoted ratings are retained in TUBE_SECTION_PARAMETER.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1963 Burroughs

Published operating points and test conditions from this source.

SECTION 1

Nixie

Other

  • Ionization Voltage

    200 V

  • Supply Voltage

    200 V

  • Peak Cathode Current

    7.5 mA

  • Typical Supply Voltage

    200 V

  • Series Resistance

    9100 ohm

  • Cathode Current Minimum

    4 mA

  • Cathode Current Maximum

    7 mA

Data set 02

1971 Nixie RFT

Published operating points and test conditions from this source.

SECTION 1

Nixie

Other

  • Comparable RFT Type

    Z5680M

    Catalog cross-reference; comparable types are not guaranteed identical

  • Minimum Operating Supply Voltage

    200 V

    Published for comparable RFT type Z5680M

  • Cathode Current Minimum

    4 mA

    Published for comparable RFT type Z5680M

  • Cathode Current Maximum

    7 mA

    Published for comparable RFT type Z5680M

  • Peak Cathode Current

    25 mA

    Published for comparable RFT type Z5680M

  • Ambient Temperature Minimum

    -10 °C

    Published for comparable RFT type Z5680M

  • Ambient Temperature Maximum

    50 °C

    Published for comparable RFT type Z5680M

  • Maximum Bulb Height

    100 mm

    Published for comparable RFT type Z5680M

  • Maximum Bulb Diameter

    50 mm

    Published for comparable RFT type Z5680M

Characteristic

  • Anode Striking Voltage

    150 V

    Published for comparable RFT type Z5680M

  • Anode Maintaining Voltage

    140 V

    Published for comparable RFT type Z5680M

  • Anode Extinction Voltage

    120 V

    Published for comparable RFT type Z5680M