Data set 01
1963 Burroughs
Published operating points and test conditions from this source.
Nixie
Other
Supply Voltage
170 V
Total Cathode Current
12 mA
Individual Cathode Current General
1.7 mA
K1-K12 except K8/K10
Individual Cathode Current K10/K13
1.5 mA
Individual Cathode Current K8
3 mA
Series Anode Resistance
68000 ohm