Skip to main content

Specialized - Thyratron ·Thyratron

AX105

Radiation-cooled mercury-vapor tetrode thyratron for controlled switching and power-conversion service in industrial electronic equipment.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
5 V / 10 A

Description

Radiation-cooled mercury-vapor thyratron tetrode.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
5 V
Nominal heater current
10 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Thyratron

X-ray radiationInterelectrode capacitances
Max cathode current
4 A

Published filament, heating time, tube drop, forward/inverse voltage, current, grid, ionization and deionization data reviewed.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1958 Amperex Industrial

Published operating points and test conditions from this source.

SECTION 1

Thyratron

Characteristic

  • Filament voltage

    5 V

    ThyratronService

  • Filament current

    10 A

    ThyratronService

  • Filament heating time

    300 s

    ThyratronService

  • Tube voltage drop

    16 V

    ThyratronService

  • Ionization time

    10 us

    ThyratronService

  • Deionization time

    1000 us

    ThyratronService

Other

  • Maximum peak forward voltage

    10000 V

    ThyratronService

  • Maximum peak inverse voltage

    10000 V

    ThyratronService

  • Maximum peak anode current

    8 A

    ThyratronService

  • Maximum average anode current

    4 A

    ThyratronService

  • Maximum grid voltage

    -500 V

    ThyratronService

Data set 02

1963 Amperex Condensed

Published operating points and test conditions from this source.

SECTION 1

Thyratron

Other

  • Heater or filament voltage

    5 V

    Section1

  • Heater or filament current

    10 A

    Section1

  • Peak forward voltage maximum

    10000 V

    Thyratron

  • Peak inverse voltage maximum

    10000 V

    Thyratron

  • Peak anode current maximum

    8 A

    Thyratron

  • Average anode current maximum

    4 A

    Thyratron

  • Maximum grid voltage

    -500 V

    Thyratron

  • Recommended temperature range

    +40 to +80 °C

    Thyratron

Characteristic

  • Filament heating time

    300 s

    Thyratron

  • Tube voltage drop

    16 V

    Thyratron

  • Ionization time

    10 µs

    Thyratron

  • Deionization time

    1000 µs