Data set 01
1953 AEG
Published operating points and test conditions from this source.
IgnitronPowerSwitch
Construction
Cooling method
Water
Other
Maximum switching capacity
600 kVA
AntiParallelPair
Peak anode current
2800 A
Specialized - Ignitron ·IgnitronPowerSwitch
Water-cooled metal ignitron for high-power industrial switching. Its mercury-pool discharge path handles extremely large currents.
Water-cooled metal ignitron for high-power industrial switching.
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
Ignitron; represented as Thyratron in canonical TubeType and Other in canonical SectionType.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Cooling method
Water
Maximum switching capacity
600 kVA
AntiParallelPair
Peak anode current
2800 A