Data set 01
1955 Marconi
Published operating points and test conditions from this source.
Rectifier
Other
Filament voltage
5 V
Filament current
30 A
Peak inverse voltage
22000 V
Peak anode current
40 A
Average anode current
10 A
Minimum pre-heating time
120 s
Maximum DC output voltage
10.5 kV
3PhaseHalfWave
Maximum DC output current
30 A
3PhaseHalfWave
Maximum DC output voltage
21 kV
3PhaseFullWave
Maximum DC output current
30 A
3PhaseFullWave
Characteristic
Forward arc voltage drop
15 V
Construction
Filling
Mercury vapor
Cooling
Air blast / source-specified thermal control