Data set 01
194X Wehrmacht Rohren
Published operating points and test conditions from this source.
Hexode
Characteristics
Transconductance
1500 uS
Other
Maximum anode voltage
200 V
Hexode ·Hexode
German triode valve with published operating data and limiting ratings; available source material does not establish a narrower functional role confidently.
AH100: triode valve with published operating data and limiting ratings. The approved German-language datasheet was translated and interpreted by technical meaning.
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
Published ratings and characteristic constants promoted where applicable. Telefunken AH100 is a mixer HEXODE, not a triode, usable as amplifier or frequency converter. Maximum plate voltage 250 V; screen grids 2 and 4 jointly maximum 150 V, combined screen dissipation 1 W; plate dissipation maximum 2 W, cathode current maximum 15 mA. Typical amplification plate voltage 200 V, screen 100 V, gm about 1.5 mA/V, rp about 0.25 MΩ.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Transconductance
1500 uS
Maximum anode voltage
200 V