Voltage - Triode (single) ·Triode
ACP
Indirectly heated AC-mains triode for low-frequency amplification or detector service.
- Sections
- 1
- Base
- -
- Socket code
- -
- Base pins
- 5
- Nominal heater
- 4 V / 1 A
Description
Indirectly heated A.C. mains triode for L.F. amplification or detection. The datasheet provides ratings, characteristics and application guidance for the intended service.
General specifications
Tube and section characteristics
Properties common to every published source and operating point.
Heater and base
- Base
- -
- Socket code
- -
- Base pins
- 5
- Nominal heater voltage
- 4 V
- Nominal heater current
- 1 A
- Parallel heater voltage
- -
- Parallel heater current
- -
- Series capable
- No
Terminal pinout
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
Section ratings
1 physical section, each with unique specifications.
Section 1
Triode
- Plate resistance
- 2650 Ω
- Transconductance
- 0.00375 S
- Amplification factor
- 10
- Max plate voltage
- 200 V
- Max plate dissipation
- 4 W
Indirectly heated A.C. mains triode for L.F. amplification or detection.
Source-dependent data
Operating conditions by source
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.