Skip to main content

Voltage - Triode (single) ·Triode

AC100

Triode valve with published operating data and limiting ratings; available source material does not establish a narrower functional application confidently.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
P5A
Base pins
5
Nominal heater
4 V / 650 mA

Description

AC100: triode valve with published operating data and limiting ratings. The approved German-language datasheet was translated and interpreted by technical meaning.

Socket description

Europe side-contact 5

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
P5A
Base pins
5
Nominal heater voltage
4 V
Nominal heater current
650 mA
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Transconductance
0.0027 S
Amplification factor
30
Max plate voltage
250 V
Max plate dissipation
2 W

Published ratings and characteristic constants promoted where applicable.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

194X Wehrmacht Rohren

Published operating points and test conditions from this source.

SECTION 1

Triode

Characteristics

  • Heater voltage

    4 V

  • Transconductance

    2700 uS

  • Amplification factor

    30

Other

  • Maximum anode voltage

    250 V

  • Maximum anode dissipation

    2 W