Data set 01
1971 English Electric Valve
Published operating points and test conditions from this source.
Rectifier
Other
DC Output Voltage
23 kV
ThreePhase
DC Output Current
3 A
ThreePhase
Characteristic
NominalImpedance
130 Ohm
At 3.0 A
Rectifier - Half Wave ·Rectifier
Directly heated high-vacuum rectifier designed particularly for three-phase high-voltage rectifier circuits, providing ampere-class output and substantial inverse-voltage capability.
High-vacuum rectifier rated to 25 kV peak inverse voltage and designed for three-phase rectifier circuits.
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
DC Output Voltage
23 kV
ThreePhase
DC Output Current
3 A
ThreePhase
NominalImpedance
130 Ohm
At 3.0 A