Data set 01
1968 General Electric Co
Published operating points and test conditions from this source.
Triode
Other
PeakAnodeVoltage
1000 V
Peak Cathode Current
700 mA
Pulse<2us
DCGridCurrentMax
6 mA
small power ampl ifier or frequency multi pi ier at frequencies up to
1250 MHz
Heater voltage
6.3 V
Heater current (approx) - A2521
300 mA
Heater current (approx) - CV2453
370 mA
DC anode voltage
250 V
MAXIMUM RATINGS
Peak anode voltage
1000 V
MAXIMUM RATINGS
Anode dissipation
2.5 W
MAXIMUM RATINGS
DC grid current
6 mA
MAXIMUM RATINGS
DC cathode current
25 mA
MAXIMUM RATINGS
Peak cathode current (pulse duration 2/ls)
700 mA
MAXIMUM RATINGS
Negative dc grid voltage
20 V
MAXIMUM RATINGS
Peak heater-cathode voltage
100 V
MAXIMUM RATINGS
Frequency 1250 900 400
200 MHz
Typical Operation
Vb 180 180 180
180 V
Typical Operation
la 16 16 16
16 mA
Typical Operation
6f (to
3 dB
Typical Operation
6f (to 3 dB) 20 50 6
4 MHz
Typical Operation
tPower gain 9 10 17
14.5 dB
Typical Operation
t j Noise factor 11 1 9 5 6 7
4.6 dB
Typical Operation
DC anode voltage
250 V
Typical Operation
Anode dissipation
2.5 W
Typical Operation
Peak anode current
100 mA
Typical Operation
DC grid current
6 mA
Typical Operation
Positive dc cathode to grid voltage
20 V
Typical Operation
Frequency 400
900 MHz
Typical Operation as Amplifier
DC anode voltage 250
150 V
Typical Operation as Amplifier
Anode dissipation 2
2.4 W
Typical Operation as Amplifier
DC anode cu rrent 18
20 mA
Typical Operation as Amplifier
DC grid current 4 5
2.5 mA
Typical Operation as Amplifier
Positive dc cathode to grid voltage 10 5
5 V
Typical Operation as Amplifier
Driving power 0 3
0.45 W
Typical Operation as Amplifier
Load power (approx 2 6
0.9 W
Typical Operation as Amplifier
Frequency-in 200 133 3 450 300
416.6 MHz
Typical Operation as Frequency Multiplier
Frequency-out 400 400 900 900
1250 MHz
Typical Operation as Frequency Multiplier
Va 200 200 140 90
130 V
Typical Operation as Frequency Multiplier
r g 2 4 2 5 2 4 2 5
2.4 W
Typical Operation as Frequency Multiplier
la 20 15 20 20
18.5 mA
Typical Operation as Frequency Multiplier
Ig 3 5 1 5 3 5 3 0
1.5 mA
Typical Operation as Frequency Multiplier
+Vkil 20 20 15 10
10.5 V
Typical Operation as Frequency Multiplier
Pdr 0 6 0 55 0 6 1 2
0.22 W
Typical Operation as Frequency Multiplier
PL (approx) 1 8 0 75 0 7 0 3
0.05 W
Typical Operation as Frequency Multiplier
Characteristic
Cathode plus heater to grid
3.5 pF
CAPACITANCES (Measured on a cold unscreened valve)
Anode to grid
1.6 pF
CAPACITANCES (Measured on a cold unscreened valve)
Cathode plus heater to anode
0.06 pF
CAPACITANCES (Measured on a cold unscreened valve)
DC anode voltage
130 V
CAPACITANCES (Measured on a cold unscreened valve)
DC anode current
16 mA
CAPACITANCES (Measured on a cold unscreened valve)
Negative dc grid voltage (approx)
1 V
CAPACITANCES (Measured on a cold unscreened valve)