Data set 01
1955 Marconi
Published operating points and test conditions from this source.
Triode
Other
Heater voltage
6.3 V
Published heater rating.
Heater current
2.5 A
Published heater rating.
Peak heater-cathode voltage
300 V
Maximum rating.
Plate voltage
250 V
Maximum per triode system.
Plate dissipation
13 W
Maximum per triode system.
Transconductance
7500 uS
Characteristic per triode system.
Scanning-booster peak inverse voltage
17000 V
Maximum scanning-booster rating; pulse duration limited to 10 us and 15% of scanning cycle.