Data set 01
1958 Brimar Radio Valve No 7
Published operating points and test conditions from this source.
Pentode
Characteristics
Anode Voltage
250 V
Screen Voltage
100 V
Anode Current
10 mA
Screen Current
3.3 mA
Cathode Bias Resistor
100 ohm
Voltage Pentode - Remote Cutoff (single) ·Pentode
High-slope Brimar variable-mu RF pentode designed for television and FM IF stages using automatic gain control. It combines substantial transconductance with controlled cutoff for wideband gain-regulated amplification.
The BRIMAR 9D7 is a high-slope vari-mu RF pentode for television and FM IF stages using automatic gain control.
Small-button Noval 9-contact
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
High-slope vari-mu RF pentode.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Anode Voltage
250 V
Screen Voltage
100 V
Anode Current
10 mA
Screen Current
3.3 mA
Cathode Bias Resistor
100 ohm