Data set 01
1948 Brimar Radio Valve Manual
Published operating points and test conditions from this source.
Pentode
Characteristics
Cutoff characteristic
Variable-mu
Voltage Pentode - Remote Cutoff (single) ·Pentode
Brimar variable-mu RF pentode for controlled high-frequency amplification. Its gradual cutoff characteristic supports automatic gain regulation in receiver RF or IF signal stages.
Vari-mu RF pentode.
Small-button Noval 9-contact
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
Vari-mu RF pentode.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Cutoff characteristic
Variable-mu
Data set 02
Published operating points and test conditions from this source.
Anode Voltage
250 V
Anode Current
10.5 mA
Screen Voltage
125 V
Screen Current
2.6 mA
Control Grid Voltage
-3 V
Control Grid Voltage at Low Transconductance
-52 V