Data set 01
1940 RCA
Published operating points and test conditions from this source.
Triode
Characteristics
Heater or filament voltage
6 V
Published nominal value
Heater or filament current
285 A
Published nominal value
Cooling
Water and forced air
Water-cooled plate plus forced-air header/seal cooling
Other
Maximum plate dissipation
25000 W
Published maximum
Maximum full-rating frequency
30 MHz
Full plate voltage, plate input, and grid current
Maximum reduced-rating frequency
100 MHz
Reduced ratings
Maximum plate input
40 kW
Published maximum
Typical RF power output
29.5 kW
Grounded-filament RF service example
Typical RF power output
32.5 kW
Grounded-grid RF service example