Data set 01
1971 RCA HB3 Binder 5 of 7
Published operating points and test conditions from this source.
Triode
Other
Heater voltage nominal
8.4 V
Heater current nominal
450 mA
Pentode
Other
Heater voltage nominal
8.4 V
Heater current nominal
450 mA
Voltage Triode Pentode ·Pentode-Triode
Medium-mu triode plus sharp-cutoff pentode, heater variant of the 6BH8.
8BH8 is explicitly specified as the same as 6BH8 except for its heater characteristics; the supplied sheet is reference-only.
Small-button Noval 9-contact
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
| Terminal | Section | Connection | Evidence |
|---|---|---|---|
| PIN12K | B | K — Cathode EIA transcription; manufacturer confirmation pending | Unverified EIA Base Connections, printed page 131, 9DX |
| PIN22G1 | B | G1 — Control Grid EIA transcription; manufacturer confirmation pending | Unverified EIA Base Connections, printed page 131, 9DX |
| PIN32P | B | P — Plate (Anode) EIA transcription; manufacturer confirmation pending | Unverified EIA Base Connections, printed page 131, 9DX |
| PIN4H | — | H — Heater EIA transcription; manufacturer confirmation pending | Unverified EIA Base Connections, printed page 131, 9DX |
| PIN5H | — | H — Heater EIA transcription; manufacturer confirmation pending | Unverified EIA Base Connections, printed page 131, 9DX |
| PIN61G3 | A | G3 — Suppressor GridGroup 9DX6 EIA transcription; manufacturer confirmation pending | Unverified EIA Base Connections, printed page 131, 9DX |
| PIN6IS | A | IS — Internal ScreenGroup 9DX6 EIA transcription; manufacturer confirmation pending | Unverified EIA Base Connections, printed page 131, 9DX |
| PIN61K | A | K — CathodeGroup 9DX6 EIA transcription; manufacturer confirmation pending | Unverified EIA Base Connections, printed page 131, 9DX |
| PIN71G1 | A | G1 — Control Grid EIA transcription; manufacturer confirmation pending | Unverified EIA Base Connections, printed page 131, 9DX |
| PIN81G2 | A | G2 — Screen Grid EIA transcription; manufacturer confirmation pending | Unverified EIA Base Connections, printed page 131, 9DX |
| PIN91P | A | P — Plate (Anode) EIA transcription; manufacturer confirmation pending | Unverified EIA Base Connections, printed page 131, 9DX |
2 physical sections, each with unique specifications.
Section 1
No fixed ratings are recorded for this section.
Reference-only sheet; parent electrical data not present in currently available approved outputs.
Section 2
No fixed ratings are recorded for this section.
Reference-only sheet; parent electrical data not present in currently available approved outputs.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Heater voltage nominal
8.4 V
Heater current nominal
450 mA
Heater voltage nominal
8.4 V
Heater current nominal
450 mA