8846

Massive water-cooled ceramic-metal triode for dielectric and induction heating, pulse modulation, and high-power RF service. Rated around 140 kW plate dissipation, with pulse switching capability approaching 8 MW at tens of kilovolts.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
16.5 V / 325 A

Description

The ML-8846 is a general-purpose high-power triode suit- water-jacket coupling. The heavy-wall anode will dissipate able for use in dielectric and induction heating, pulse modu- up to 140 kW with a water flow of 60 gpm. The maximum lation and similar applications. This tube features rugged, CW plate-voltage rating of 16 kV applies at frequencies up ceramic-and-metal, coaxial construction with high-dissipation, to 30 MHz. The tube may be operated up to 88 MHz with a low-inductance rf terminals. The cathode consists of sturdy, reduction in ratings. In pulse service the tube is capable of stress-free, thoriated-tungsten filaments. This tube is suitable switching up to 8 Mw with plate voltages up to 35 kV. for cavity operation and its low plate impedance adapts it to Except for minor dimensional differences, the ML-8846 can

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
16.5 V
Nominal heater current
325 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Amplification factor
30
Max plate voltage
40000 V
Max plate dissipation
140000 W
Max grid dissipation
25000 W
Max cathode current
360 mA

Promoted ratings/characteristics mapped from printed headings; device/service-specific values retained in parameters.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1971 Machlette Laboratories

Published operating points and test conditions from this source.

SECTION 1

Triode

Other

  • Published value

    8

    8 Mw Pulse Power

  • The ML

    8846

    The ML-8846 is a general-purpose high-power triode suit- water-jacket coupling. The heavy-wall anode will dissipate

  • able for use in dielectric and induction heating, pulse modu- up to [1]

    140 mA

    able for use in dielectric and induction heating, pulse modu- up to 140 kW with a water flow of 60 gpm. The maximum

  • able for use in dielectric and induction heating, pulse modu- up to [2]

    60 mA

    able for use in dielectric and induction heating, pulse modu- up to 140 kW with a water flow of 60 gpm. The maximum

  • lation and similar applications. This tube features rugged, CW plate-voltage rating of

    16

    lation and similar applications. This tube features rugged, CW plate-voltage rating of 16 kV applies at frequencies up

  • ceramic-and-metal, coaxial construction with high-dissipation, to [1]

    30 mA

    ceramic-and-metal, coaxial construction with high-dissipation, to 30 MHz. The tube may be operated up to 88 MHz with a

  • ceramic-and-metal, coaxial construction with high-dissipation, to [2]

    88 mA

    ceramic-and-metal, coaxial construction with high-dissipation, to 30 MHz. The tube may be operated up to 88 MHz with a

  • stress-free, thoriated-tungsten filaments. This tube is suitable switching up to [1]

    8

    stress-free, thoriated-tungsten filaments. This tube is suitable switching up to 8 Mw with plate voltages up to 35 kV.

  • stress-free, thoriated-tungsten filaments. This tube is suitable switching up to [2]

    35

    stress-free, thoriated-tungsten filaments. This tube is suitable switching up to 8 Mw with plate voltages up to 35 kV.

  • for cavity operation and its low plate impedance adapts it to Except for minor dimensional differences, the ML

    8846

    for cavity operation and its low plate impedance adapts it to Except for minor dimensional differences, the ML-8846 can

  • Filament Voltage

    165

    Filament Voltage .................................................. 165 V

  • Filament Current at [1]

    16.5 V

    Filament Current at 16.5 volts 325 A

  • Filament Current at [2]

    325 V

    Filament Current at 16.5 volts 325 A

  • Filament Starting Current, maximum

    800 mA

    Filament Starting Current, maximum .... 800 A

  • Filament Cold Resistance

    0.0052

    Filament Cold Resistance 0.0052 ohm

  • Amplification Factor

    30

    Amplification Factor .................................................. 30

  • Maximum Water Pressure

    75 mA

    Maximum Water Pressure .................................................. 75 psi

  • Maximum Outlet Water Temperature

    70 mA

    Maximum Outlet Water Temperature 70 °C

  • Air Flow on Envelope and Seals, approximate

    250 mA

    Air Flow on Envelope and Seals, approximate .................................................. 250 cfm

  • Maximum Envelope Temperature

    200 mA

    Maximum Envelope Temperature .................................................. 200 °C

  • WARNING: This electron tube when operating at peak voltages in excess of

    15 mA

    WARNING: This electron tube when operating at peak voltages in excess of 15 kv may give off x-rays, which can be harmful unless adequately

  • Item Part No. D C Plate Voltage [1]

    35

    Item Part No. D C Plate Voltage ... 35 35 kV

  • Item Part No. D C Plate Voltage [2]

    35

    Item Part No. D C Plate Voltage ... 35 35 kV

  • D C Grid Voltage ..o [1]

    -2000

    D C Grid Voltage ..o -2000 -2000 V

  • D C Grid Voltage ..o [2]

    -2000

    D C Grid Voltage ..o -2000 -2000 V

  • Pulse Positive Grid Voltage [1]

    2000

    Pulse Positive Grid Voltage ................. 2000 2400 v

  • Pulse Positive Grid Voltage [2]

    2400

    Pulse Positive Grid Voltage ................. 2000 2400 v

  • Pulse Plate Current [1]

    200

    Pulse Plate Current ... 200 300 2

  • Pulse Plate Current [2]

    300

    Pulse Plate Current ... 200 300 2

  • Pulse Plate Current [3]

    2

    Pulse Plate Current ... 200 300 2

  • Pulse Grid Current [1]

    100

    Pulse Grid Current ... . 100 60 a

  • Pulse Grid Current [2]

    60

    Pulse Grid Current ... . 100 60 a

  • Pulse Driving Power [1]

    400 kW

    Pulse Driving Power .. 400 300 kw

  • Pulse Driving Power [2]

    300 kW

    Pulse Driving Power .. 400 300 kw

  • Pulse Power QOutput [1]

    6.6

    Pulse Power QOutput ........ 6.6 8.4 Mw

  • Pulse Power QOutput [2]

    8.4

    Pulse Power QOutput ........ 6.6 8.4 Mw

  • Plate Output Voltage [1]

    33

    Plate Output Voltage . 33 28 kv

  • Plate Output Voltage [2]

    28

    Plate Output Voltage . 33 28 kv

  • Small Gasket for Mounting Socket ..............ccocvininiin. P

    12272 mA

    Small Gasket for Mounting Socket ..............ccocvininiin. P-12272 +For applications requiring longer pulse duration or higher duty

  • Data Sheet No. ST

    1006 mA

    Data Sheet No. ST-1006. MAXIMUM FREQUENCY RATINGS

  • OPERATING CONDITIONS Frequency in Megahertzes [P R [1]

    30 MHz

    OPERATING CONDITIONS Frequency in Megahertzes [P R 30 60 88

  • OPERATING CONDITIONS Frequency in Megahertzes [P R [2]

    60 MHz

    OPERATING CONDITIONS Frequency in Megahertzes [P R 30 60 88

  • OPERATING CONDITIONS Frequency in Megahertzes [P R [3]

    88 MHz

    OPERATING CONDITIONS Frequency in Megahertzes [P R 30 60 88

  • Percent Maximum Rated Plate Voltage and Plate Input [1]

    100 mA

    Percent Maximum Rated Plate Voltage and Plate Input 100 78 56

  • Percent Maximum Rated Plate Voltage and Plate Input [2]

    78 mA

    Percent Maximum Rated Plate Voltage and Plate Input 100 78 56

  • Percent Maximum Rated Plate Voltage and Plate Input [3]

    56 mA

    Percent Maximum Rated Plate Voltage and Plate Input 100 78 56

  • Frequency ........c.oooooovviiiiiiii, [1]

    88

    Frequency ........c.oooooovviiiiiiii, 88 30 MH: properly controlled. The tube must, therefore, be protected by

  • Frequency ........c.oooooovviiiiiiii, [2]

    30

    Frequency ........c.oooooovviiiiiiii, 88 30 MH: properly controlled. The tube must, therefore, be protected by

  • D C Plate Voltage ..............ccccooevein [1]

    9000

    D C Plate Voltage ..............ccccooevein. 9000 16000 V

  • D C Plate Voltage ..............ccccooevein [2]

    16000

    D C Plate Voltage ..............ccccooevein. 9000 16000 V

  • D C Grid Voltage .............coocooveiin [1]

    -3200

    D C Grid Voltage .............coocooveiin. -3200 3200 V

  • D C Grid Voltage .............coocooveiin [2]

    3200

    D C Grid Voltage .............coocooveiin. -3200 3200 V

  • D C Plate Current [1]

    20

    D C Plate Current ................................ 20 20 A to diverting the energy from the tube, as well as the amount of

  • D C Plate Current [2]

    20

    D C Plate Current ................................ 20 20 A to diverting the energy from the tube, as well as the amount of

  • D C Grid Current [1]

    2.5

    D C Grid Current ... 2.5 40 A energy expended in the tube during this interval.

  • D C Grid Current [2]

    40

    D C Grid Current ... 2.5 40 A energy expended in the tube during this interval.

  • Plate Input [1]

    170 mA

    Plate Input ... 170 300 kW In addition to the normal circuit breakers and overload re-

  • Plate Input [2]

    300 mA

    Plate Input ... 170 300 kW In addition to the normal circuit breakers and overload re-

  • Plate Dissipation [1]

    140 kW

    Plate Dissipation .......................... 140 140 kW lays, it is necessary that a fast-acting electronic protective

  • Plate Dissipation [2]

    140 kW

    Plate Dissipation .......................... 140 140 kW lays, it is necessary that a fast-acting electronic protective

  • Power Amplifier and Oscillator, Grid-Drive Circuit —

    30 MHz

    Power Amplifier and Oscillator, Grid-Drive Circuit — 30 MHz output of the plate supply filter, if used, to dissipate the filrer-

  • D C Plate Voltage [1]

    8000

    D C Plate Voltage ................ 8000 12000 15000 V circuit energy as well as the rectifier output. The complete

  • D C Plate Voltage [2]

    12000

    D C Plate Voltage ................ 8000 12000 15000 V circuit energy as well as the rectifier output. The complete

  • D C Plate Voltage [3]

    15000

    D C Plate Voltage ................ 8000 12000 15000 V circuit energy as well as the rectifier output. The complete

  • D C Grid Voltage [1]

    -750

    D C Grid Voltage ............... -750 -1100 -1400 V

  • D C Grid Voltage [2]

    -1100

    D C Grid Voltage ............... -750 -1100 -1400 V

  • D C Grid Voltage [3]

    -1400

    D C Grid Voltage ............... -750 -1100 -1400 V

  • Peak R F Grid Voltage [1]

    1210

    Peak R F Grid Voltage .......... 1210 1750 2200 v

  • Peak R F Grid Voltage [2]

    1750

    Peak R F Grid Voltage .......... 1210 1750 2200 v

  • Peak R F Grid Voltage [3]

    2200

    Peak R F Grid Voltage .......... 1210 1750 2200 v

  • Peak R F Plate Voltage [1]

    6600

    Peak R F Plate Voltage .......... 6600 10300 12800 v the inception of a “fault”, and in most cases the time interval

  • Peak R F Plate Voltage [2]

    10300

    Peak R F Plate Voltage .......... 6600 10300 12800 v the inception of a “fault”, and in most cases the time interval

  • Peak R F Plate Voltage [3]

    12800

    Peak R F Plate Voltage .......... 6600 10300 12800 v the inception of a “fault”, and in most cases the time interval

  • D C Plate Current [1]

    9.7 mA

    D C Plate Current .................. 9.7 14.3 184 A should not be allowed to exceed approximately ten micro-

  • D C Plate Current [2]

    14.3 mA

    D C Plate Current .................. 9.7 14.3 184 A should not be allowed to exceed approximately ten micro-

  • D C Plate Current [3]

    184 mA

    D C Plate Current .................. 9.7 14.3 184 A should not be allowed to exceed approximately ten micro-

  • D C Grid Current [1]

    2.1 s

    D C Grid Current .................. 2.1 2.9 3.0 A seconds. For some basic electronic-crowbar fault-protection

  • D C Grid Current [2]

    2.9 s

    D C Grid Current .................. 2.1 2.9 3.0 A seconds. For some basic electronic-crowbar fault-protection

  • D C Grid Current [3]

    3 s

    D C Grid Current .................. 2.1 2.9 3.0 A seconds. For some basic electronic-crowbar fault-protection

  • R F Load Resistance [1]

    380 ohm

    R F Load Resistance .............. 380 400 380 ohms

  • R F Load Resistance [2]

    400 ohm

    R F Load Resistance .............. 380 400 380 ohms

  • R F Load Resistance [3]

    380 ohm

    R F Load Resistance .............. 380 400 380 ohms

  • Driving Power, approximate [1]

    2.5 mA

    Driving Power, approximate .. 2.5 49 7.2 kW

  • Driving Power, approximate [2]

    49 mA

    Driving Power, approximate .. 2.5 49 7.2 kW

  • Driving Power, approximate [3]

    7.2 mA

    Driving Power, approximate .. 2.5 49 7.2 kW

  • Power Output, approximate [1]

    58 mA

    Power Output, approximate .. 58 132 215 kW protection device, refer to the references listed.

  • Power Output, approximate [2]

    132 mA

    Power Output, approximate .. 58 132 215 kW protection device, refer to the references listed.

  • Power Output, approximate [3]

    215 mA

    Power Output, approximate .. 58 132 215 kW protection device, refer to the references listed.

  • D C Plate Voltage

    35

    D C Plate Voltage ... 35 kV

  • Peak Plate Voltage

    40

    Peak Plate Voltage ... 40 kv

  • Peak Negative Grid Voltage

    -7000

    Peak Negative Grid Voltage .. -7000 v

  • Pulse Cathode Current

    360

    Pulse Cathode Current ... 360 a

  • Grid Dissipation

    25 kW

    Grid Dissipation ............ 25 kW

  • Published value

    1

    1. W. N. Parker and M. V. Hoover, "Gas Tubes Protect High Power

  • Plate Dissipation .................ccooooeoiii [1]

    140 kW

    Plate Dissipation .................ccooooeoiii 140 kW Transmitters”, Electronics, 29, 144, January 1956.

  • Plate Dissipation .................ccooooeoiii [2]

    29 kW

    Plate Dissipation .................ccooooeoiii 140 kW Transmitters”, Electronics, 29, 144, January 1956.

  • Plate Dissipation .................ccooooeoiii [3]

    144 kW

    Plate Dissipation .................ccooooeoiii 140 kW Transmitters”, Electronics, 29, 144, January 1956.

  • Plate Dissipation .................ccooooeoiii [4]

    1956 kW

    Plate Dissipation .................ccooooeoiii 140 kW Transmitters”, Electronics, 29, 144, January 1956.

  • Pulse Duration, approXimate .......ccocooeer oo [1]

    1000 mA

    Pulse Duration, approXimate .......ccocooeer oo 1000 pst 2. H. D. Doolittle, “High Power Hydrogen Thyratrons”, Cathode

  • Pulse Duration, approXimate .......ccocooeer oo [2]

    2 mA

    Pulse Duration, approXimate .......ccocooeer oo 1000 pst 2. H. D. Doolittle, “High Power Hydrogen Thyratrons”, Cathode