Power - Beam (NOT sweep) (over 1000V 100W) ·BeamPower

8807

Forced-air Cermolox beam-power tube for VHF television and linear RF power service, designed for very-high-power broadcast and communications transmitters.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
B9A
Base pins
9
Nominal heater
9.5 V / 145 A

Description

Cermolox forced-air-cooled beam-power tube for VHF-TV and linear RF power service.

Socket description

Small-button Noval 9-contact

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
B9A
Base pins
9
Nominal heater voltage
9.5 V
Nominal heater current
145 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Beam Power

X-ray radiationInterelectrode capacitances
Amplification factor
10
Max plate voltage
10000 V
Max screen voltage
2000 V
Max plate dissipation
15000 W
Max cathode current
6 A

Published screen-to-control-grid mu factor promoted.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1971 RCA HB3 Binder 6 of 7

Published operating points and test conditions from this source.

SECTION 1

Beam Power

Other

  • Heater/filament voltage

    9.5 V

  • Heater/filament current

    145 A

  • Maximum plate voltage

    10000 V

  • Maximum screen voltage

    2000 V

  • Maximum plate current

    6 A

  • Plate dissipation

    15000 W

  • Minimum heating time

    15 s

  • Full-input frequency

    400 MHz

  • Peak sync output

    20000 W

    VHF-TV

  • Linear carrier output

    3750 W

Characteristic

  • Grid No.2 to grid No.1 mu factor

    10

Construction

  • Cooling method

    Forced air