Skip to main content

Power - Beam (NOT sweep) (over 1000V 100W) ·BeamPower

8794

Cermolox high-power beam tube for RF service through approximately 400 MHz, with 12.5 kW plate dissipation and multi-kilowatt transmitting capability.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
B9A
Base pins
9
Nominal heater
5.7 V / 125 A

Description

Cermolox high-power beam-power tube for RF service through 400 MHz.

Socket description

Small-button Noval 9-contact

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
B9A
Base pins
9
Nominal heater voltage
5.7 V
Nominal heater current
125 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Beam Power

X-ray radiationInterelectrode capacitances
Amplification factor
10
Max plate voltage
8000 V
Max screen voltage
1650 V
Max plate dissipation
12500 W
Max cathode current
4 A

Published screen-to-control-grid mu factor promoted.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1971 RCA HB3 Binder 6 of 7

Published operating points and test conditions from this source.

SECTION 1

Beam Power

Other

  • Heater/filament voltage

    5.7 V

  • Heater/filament current

    125 A

  • Maximum plate voltage

    8000 V

  • Maximum screen voltage

    1650 V

  • Maximum plate current

    4 A

  • Plate dissipation

    12500 W

  • Minimum heating time

    15 s

  • Full-input frequency

    400 MHz

  • PEP output

    10000 W

    SSB

  • FM/telegraphy output

    15000 W

Characteristic

  • Grid No.2 to grid No.1 mu factor

    10

Construction

  • Cooling method

    Forced air