Data set 01
1938 Raytheon Amateur
Published operating points and test conditions from this source.
Rectifier
Application
Application
MercuryVaporHalfWaveRectifier text
Rectifier - Half Wave ·Rectifier
Directly heated mercury-vapor high-voltage half-wave rectifier for transmitter and general power supplies. Its low arc voltage provides efficient moderate-current conversion at multi-kilovolt potentials.
Directly heated mercury-vapor high-voltage half-wave rectifier for power-supply service.
Medium-shell UX 4-contact
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
Promoted values are taken from printed General Characteristics / Maximum Ratings. Additional published conditions and operating data are preserved in parameters.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Application
MercuryVaporHalfWaveRectifier text
Data set 02
Published operating points and test conditions from this source.
HeaterVoltageNominal
2.5 V
Nominal
HeaterCurrentNominal
5 A
Nominal
Maximum Peak Inverse Voltage
10000 V
Rectified Output Current
250 mA
PeakForwardCurrent
1 A
Forward Voltage Drop
10 V
Data set 03
Published operating points and test conditions from this source.
Filament Voltage
2.5 V
Filament Current
5 A
Approximate Tube Voltage Drop
15 V
Recommended Condensed Mercury Temperature
40 C
±5 C
Initial Mercury Redistribution Heating Time
10 min
No plate voltage
Normal Filament Warm-up Before Plate Voltage
30 s
Approximate
Maximum Peak Inverse Anode Voltage
10000 V
At condensed-mercury temperature 25-60 C
Maximum Peak Anode Current
1 A
Maximum Average Anode Current
250 mA
Maximum Supply Frequency
150 Hz
At 10 kV PIV
Condensed Mercury Temperature Range
25-60 C
PIV Rating at 2 kV Service
2000 V
Peak current 2 A; average current 0.5 A; 150 Hz max
PIV Rating at 5 kV Service
5000 V
Peak current 1 A; average current 0.25 A; 1000 Hz max
Preferred Filter Type
Choke input
Greatest usable DC output current
Condenser-Input Filter Note
Peak current relatively high; capacitor voltage may approach 1.4× transformer RMS voltage
Data set 04
Published operating points and test conditions from this source.
Forward Voltage Drop
15 V
Data set 05
Published operating points and test conditions from this source.
Heater/Filament Voltage
2.5 V
Published datasheet value
Heater/Filament Current
5 A
Published datasheet value
Maximum Peak Inverse Voltage
10000 V
Published datasheet value
Maximum Average/Output Current
500 mA
Published datasheet value
Data set 06
Published operating points and test conditions from this source.
HeaterOrFilamentVoltage
2.5 V
HeaterOrFilamentCurrent
5 A
WarmupTimeMinimum
30 s
Before anode voltage
Data set 07
Published operating points and test conditions from this source.
Condensed Mercury Temperature Range
25 to 70 C
Supply Frequency Maximum
150 Hz
PIV=2000V
Supply Frequency Maximum
1000 Hz
PIV=5000V
Supply Frequency Maximum
150 Hz
PIV=10000V
Data set 08
Published operating points and test conditions from this source.
Heater or filament voltage
2.5 V
Published nominal value
Heater or filament current
5 A
Published nominal value
Warm-up delay
30 s
Recommended before applying anode voltage
Data set 09
Published operating points and test conditions from this source.
Heater/filament voltage
2.5 V
Heater/filament current
5 A
Peak inverse anode voltage
10000 V
Peak anode current
1 A
Average anode current
250 mA
Fault current
20 A
ShortDuration
Peak tube voltage drop
15 V
Conducting
Gas fill
Mercury vapor