Data set 01
1971 RCA HB3 Binder 6 of 7
Published operating points and test conditions from this source.
Klystron
Other
Heater/filament voltage
15 V
Heater/filament current
14 A
Minimum heating time
20 min
Peak beam voltage
260 kV
Pulse3.2us
Peak inverse beam voltage
50 kV
Peak beam current
270 A
Typical beam voltage
250 kV
HighOutput
Typical beam current
250 A
HighOutput
Driving power
105 W
HighOutput
Useful peak power output
21 MW
Power gain
53 dB
X-ray shielding required
Yes
HighVoltage
Characteristic
Center frequency
2856 MHz
Capacitance
Anode-to-cathode capacitance
42 pF