Data set 01
1964 RMA EIA
Published operating points and test conditions from this source.
Beam Power
Other
Filament voltage maximum
5 V
Filament starting current maximum
300 A
Plate voltage maximum
7000 V
CCS
Screen-grid voltage maximum
1500 V
CCS
Plate current maximum
4 A
CCS
Plate dissipation maximum
10000 W
CCS
Screen-grid input maximum
150 W
CCS
Control-grid input maximum
100 W
CCS
Plate voltage
5700 V
ClassB;Television;CathodeDrive;f=890MHz
Screen-grid voltage
1000 V
ClassB;Television;CathodeDrive;f=890MHz
Control-grid voltage
-40 V
ClassB;Television;CathodeDrive;f=890MHz
RF output power
5500 W
f=890MHz
Characteristics
Minimum heating time
15 s
Grid No.2 to grid No.1 mu factor
16 ratio
Va=1200V;Vg2=900V;Ia=8A
Capacitance
Grid No.1 to plate capacitance maximum
0.32 pF
Grid No.1 to filament capacitance
65 pF
Plate to filament capacitance maximum
0.04 pF
Grid No.1 to grid No.2 capacitance
70 pF
Grid No.2 to plate capacitance
13 pF