Data set 01
1964 RMA EIA
Published operating points and test conditions from this source.
TravelingWave
Other
Frequency minimum
2320 MHz
Frequency maximum
2680 MHz
Collector voltage maximum
800 V
Helix voltage maximum
500 V
Grid No.4 voltage maximum
500 V
Grid No.3 voltage maximum
300 V
Grid No.2 voltage maximum
75 V
Grid No.1 voltage maximum
20 V
Collector current maximum
500 uA
Cathode current maximum
500 uA
RF peak input maximum
300 W
RF average input maximum
1 W
Collector voltage
600 V
f=2500MHz
Helix voltage
375 V
f=2500MHz
Gain
31 dB
f=2500MHz
Saturated output power
1 mW
f=2500MHz
Noise figure
4.5 dB
f=2500MHz
Characteristics
Cold insertion loss minimum
60 dB