Data set 01
1938 RCA Transmitting Tubes
Published operating points and test conditions from this source.
Triode
Other
high as
100 MHz
high as 100 megacycles; it may be operated at reduced plate voltage and input up
services is
50 W
services is 50 watts.
D-C Plate Voltage
1250 V
D-C Plate Voltage . 1250 max. Volts
D-C Plate Current
100 mA
D-C Plate Current . 100 max. Milliamperes
Plate Input
75 W
Plate Input .. 75 max. Watts
Plate Dissipation
50 W
Plate Dissipation . 50 max. Watts
D-C Plate Voltage ... 750 1000
1250 V
D-C Plate Voltage ... 750 1000 1250 Volts
Peak R-F Grid Voltage . 90 100
115 V
Peak R-F Grid Voltage . 90 100 115 Volts
D-C Plate Current ... 50 50
50 mA
D-C Plate Current ... 50 50 50 Milliamperes
D-C Crid Current (Approx.) . 1 0.5
0 mA
D-C Crid Current (Approx.) . 1 0.5 0 Milliampere
Driving Power (Approx.)t ... 3.3 3.1
3 W
Driving Power (Approx.)t ... 3.3 3.1 3 Watts
D-C Plate Voltage
1000 V
D-C Plate Voltage ... 1000 max. Volts
D-C Grid Voltage
-400 V
D-C Grid Voltage . -400 max. Volts
D-G Pi ate Current
100 mA
D-G Pi ate Current . . 100 max. Milliamperes
D-C Grid Current
20 mA
D-C Grid Current . 20 max. Milliamperes
Plate Input
100 W
Plate Input . 100 max. Watts
Plate Dissipation
35 W
Plate Dissipation . 35 max. Watts
Power Output (Approx.) ... 42
58 W
Power Output (Approx.) ... 42 58 Watts
D-C Plate Voltage
1250 V
D-C Plate Voltage .. 1250 max. Volts
D-C Grid Voltage
-400 V
D-C Grid Voltage . -400 max. Volts
D-C Grid Current
20 mA
D-C Grid Current .. ... 20 max. Milliamperes
Plate Dissipation
50 W
Plate Dissipation .. 50 max. Watts
D-C Plate Voltage .... 750 1000
1250 V
D-C Plate Voltage .... 750 1000 1250 Volts
D-C Plate Current ... 90 90
90 mA
D-C Plate Current ... 90 90 90 Milliamperes
Grid Resistor ...-... 8750 11400
15000 Ω
Grid Resistor ...-... 8750 11400 15000 Ohms
each stated value of grid voltage should be decreased by
5 V
each stated value of grid voltage should be decreased by 5 volts and the circuit returns made to the
at frequencies higher than
60 MHz
at frequencies higher than 60 megacycles, forced cooling of the tube is recom¬
For high-frequency operation above
100 MHz
For high-frequency operation above 100 megacycles, see page 144.