Data set 01
1950 General Electric Transmitting Types
Published operating points and test conditions from this source.
Beam Power
Characteristic
HeaterOrFilamentVoltage
6.3 V
HeaterOrFilamentCurrent
2.25 A
Other
FrequencyForMaximumRatings
200 MHz
Power - Beam (NOT sweep) ·BeamPower
Twin-beam transmitting tube designed for VHF RF power-amplifier and oscillator service in push-pull circuits.
Twin-beam transmitting tube for VHF RF power-amplifier and oscillator service.
Septar 7-contact base
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
Representative row for two electrically identical beam-tetrode sections; ratings vary by service/cooling condition.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
HeaterOrFilamentVoltage
6.3 V
HeaterOrFilamentCurrent
2.25 A
FrequencyForMaximumRatings
200 MHz
Data set 02
Published operating points and test conditions from this source.
Transconductance
8500 µS
Maximum Plate Voltage
750 V
Maximum Screen Voltage
225 V
Maximum Plate Dissipation
45 W
Maximum Cathode Current
240 mA
Full-Input Operating Frequency Maximum
200 MHz
Power Output
90 W
ClassC,RF
Heater Voltage Series
12.6 V
Heater Current Series
1.125 A
Heater Voltage Parallel
6.3 V
Heater Current Parallel
2.25 A
Typical Plate Voltage
600 V
Representative published point
Typical Plate Current
200 mA
Representative published point
Data set 03
Published operating points and test conditions from this source.
Grid1AnodeCapacitancePerElement
0.12 pF
InputCapacitancePerElement
14.5 pF
OutputCapacitancePerElement
7 pF
ScreenCathodeCapacitance
65 pF
MaximumHeaterCathodePeakVoltage
100 V
Typical Plate Voltage
600 V
Typical Screen Voltage
200 V
TypicalOutputPower
58 W
Data set 04
Published operating points and test conditions from this source.
Plate voltage
750 V
RFPowerAmplifier;EachSection
Plate current
120 mA
RFPowerAmplifier;EachSection
Power output
65 W
RFPowerAmplifier
Control-grid voltage
-50 V
RFPowerAmplifier
Grid current
8 mA
RFPowerAmplifier
Screen voltage
200 V
RFPowerAmplifier