Data set 01
1950 General Electric Transmitting Types
Published operating points and test conditions from this source.
Triode
Characteristic
HeaterOrFilamentVoltage
7.5 V
HeaterOrFilamentCurrent
4 A
Other
FrequencyForMaximumRatings
250 MHz
Voltage - Triode (single) ·Triode
Thoriated-tungsten RF power triode for amplifier and oscillator service to approximately 250–300 MHz.
Thoriated-tungsten RF power triode for amplifier/oscillator service to 250 MHz at full input and 300 MHz at reduced input.
Septar 7-contact base
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
Published ratings and characteristics promoted from the supplied General Electric source.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
HeaterOrFilamentVoltage
7.5 V
HeaterOrFilamentCurrent
4 A
FrequencyForMaximumRatings
250 MHz
Data set 02
Published operating points and test conditions from this source.
Amplification Factor
31
Maximum Plate Voltage
1250 V
Maximum Plate Dissipation
75 W
Maximum Cathode Current
140 mA
Full-Input Operating Frequency Maximum
250 MHz
Power Output
120 W
ClassC,RF,ForcedAirCooling
Typical Plate Voltage
1250 V
Representative published point
Typical Plate Current
125 mA
Representative published point