Skip to main content

Nuvistor Tubes (all numbers) ·Triode

8058

Power transmitting triode for RF amplification, oscillation, modulation, or related high-power electronic service.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
B9A
Base pins
5
Nominal heater
6.3 V / 135 mA

Description

8058 — High-Mu UHF Cathode-Drive Nuvistor Triode

A high-transconductance, low-noise metal-shell Nuvistor designed for grounded-grid RF amplification up to 1,200 MHz and stable oscillator operation.

Overview

The 8058 is a high-mu Nuvistor triode developed for cathode-drive radio-frequency amplification at frequencies up to 1,200 MHz, as well as oscillator applications requiring stability over a wide frequency range. RCA explicitly specifies the 1,200 MHz application, while Siemens describes a steep-slope, low-noise UHF Nuvistor with three externally connected cathode terminals, particularly suited to common-grid amplifiers and stable oscillators.

The distinctive construction includes a plate top cap, metal-shell grid connection, and multiple cathode terminals. These features distinguish the 8058 from more conventional Nuvistor receiving triodes.

Construction, Heater, and Basing

The 8058 uses a coated, indirectly heated unipotential cathode in an MT4 metal-shell Nuvistor envelope. Its specialized E5-79 ceramic-wafer base has 12CT basing. The metal shell serves as the grid connection and the top cap is the plate.

RCA's basing diagram identifies pins 2, 4, and 8 as cathode, and pins 10 and 12 as heater. Other indexed positions are not general-purpose connections.

Heater and mechanical propertyValue
Heater voltage6.3 V, range 5.7–6.9 V
Heater current135 mA
Calculated heater power0.85 W
Peak heater-to-cathode voltage±100 V
Maximum overall length0.985 in
Maximum seated length0.780 in
Maximum diameter0.440 in
Approximate weight2.2 g
Mounting positionAny

The specialized electrode and connection arrangement is intended for high-frequency circuit layouts where connection geometry and grounding are important.

Cathode-Drive RF Amplifier Performance

RCA gives specific cathode-drive amplifier examples at three frequencies:

Parameter450 MHz700 MHz1,200 MHz
Plate supply110 V110 V110 V
Cathode resistor47 Ω47 Ω47 Ω
Average plate current10 mA10 mA10 mA
Bandwidth6 MHz12 MHz12 MHz
Power gain16.5 dB12.5 dB10.5 dB
Noise factor6.5 dB9.5 dB12.2 dB

These are representative circuit operating results; actual gain, bandwidth, and noise depend on the tuned amplifier arrangement.

The noise figures are based on an argon noise source with the input tuned for optimum value. They are circuit-specific measurements rather than intrinsic noise figures independent of the surrounding amplifier.

Class A1 Electrical Characteristics

CharacteristicTypical value
Plate supply voltage110 V
Grid supply voltage0 V
Cathode resistor47 Ω
Plate current10 mA
Transconductance12,400 µmhos (12.4 mA/V)
Amplification factor70
Plate resistanceApproximately 5,600 Ω
Grid voltage at 10 µA plate currentApproximately −5 V

The figures satisfy the approximate triode relationship μ ≈ gₘ × rₚ: 0.0124 S × 5,600 Ω ≈ 69.4.

RCA specifies initial transconductance acceptance limits of 10–14.8 mA/V and amplification factor 54–86.

Maximum Ratings

ParameterMaximum
Plate supply voltage330 V
Actual DC plate voltage150 V
Plate dissipation1.5 W
Average cathode current15 mA
Positive DC grid voltage0 V
Negative DC grid voltage55 V
Fixed-bias grid-circuit resistance0.5 MΩ
Cathode-bias grid-circuit resistance1 MΩ

The plate-supply and actual plate-electrode limits must be distinguished. Grid-circuit resistance ratings depend on the metal-shell temperature; RCA provides a temperature-dependent rating chart.

Interelectrode Capacitances

MeasurementValue
Cathode to grid, shell, and heater6.0 pF
Plate to grid, shell, and heater1.3 pF
Cathode to plate≤0.046 pF
Heater to cathode1.4 pF

The extremely small cathode-to-plate capacitance is particularly relevant to the common-grid cathode-drive amplifier configuration because it limits direct input-output electrode coupling.

Industrial Qualification

RCA documents 1,000 g impact-shock testing, variable-frequency vibration tests, low-pressure breakdown tests, heater cycling, shorts testing, and 1,000-hour conduction-life evaluation.

The variable-frequency vibration test specifies maximum output disturbances of 35 mV RMS at 50–3,000 Hz, 80 mV peak at 3–6 kHz, and 700 mV peak at 6–15 kHz, under the stated 1 g test arrangement.

The low-pressure test simulates 100,000 feet altitude using 250 V RMS applied between plate and other electrodes. RCA also specifies at least 2,000 heater cycling operations under the defined test.

Siemens separately describes long-life and reliability characteristics, including a service-life specification exceeding 10,000 hours under its quality requirements.

Technical Summary

The 8058 is a 6.3 V / 135 mA high-mu UHF Nuvistor triode for cathode-drive common-grid RF amplification up to 1,200 MHz and stable oscillator service. It has approximately 70 amplification factor, 12.4 mA/V transconductance, 5.6 kΩ plate resistance, and 10 mA plate current at its principal operating point.

Its top-cap plate, metal-shell grid, three cathode terminals, extremely small cathode-to-plate capacitance, and extensive industrial qualification make it a specialized high-frequency amplifier tube.

Socket description

Small-button Noval 9-contact

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
B9A
Base pins
5
Nominal heater voltage
6.3 V
Nominal heater current
135 mA
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Plate resistance
5600 Ω
Transconductance
0.0124 S
Amplification factor
70
Max plate voltage
150 V
Max plate dissipation
1.5 W
Max cathode current
15 mA

Published promoted values applied where semantically applicable; additional source-table values retained in TUBE_SECTION_PARAMETER.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1963 Siemens

Published operating points and test conditions from this source.

SECTION 1

Triode

Other

  • Heater voltage

    6.3 V

  • Heater current

    135 mA

Characteristics

  • Transconductance

    12400 µS

    Nominal/Bogey

Data set 02

1971 RCA HB3 Binder 3 of 7

Published operating points and test conditions from this source.

SECTION 1

Triode

Characteristics

  • Heater Voltage, AC or DC

    6.3 V

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • /~"\ — published value 1

    6.3 mA

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • /~"\ — published value 2

    135 mA

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Cathode to plate

    0.046 mA

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Heater to cathode

    1.4 pF

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Amplification Factor

    70

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Plate Resistance (Approx.)

    5600

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Transconductance

    12400

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • DC Plate Current

    10 mA

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Cutoff DC Grid Voltage for Ib = 10 µA — published value 1

    10 V

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Cutoff DC Grid Voltage for Ib = 10 µA — published value 2

    -5 V

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Heater Voltage

    6.3 V

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Plate Supply Voltage

    10 V

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Grid Supply Voltage

    0 V

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Plate Supply Voltage

    330 V

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • DC Plate Voltage

    150 V

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Peak Heater-Cathode Voltage

    100 V

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Heater Voltage, AC or DC — published value 1

    5.7 V

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Heater Voltage, AC or DC — published value 2

    6.9 V

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Average Cathode Current

    15 mA

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • For fixed-bias operation

    0.5

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Pin 10 -Heater

    10

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Pi n 12 -Heater

    12

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Frequency — published value 1

    450

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Frequency — published value 2

    700

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Frequency — published value 3

    1200

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Heater Voltage — published value 1

    6.3 V

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Heater Voltage — published value 2

    6.3 V

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Heater Voltage — published value 3

    6.3 V

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Plate Supply Voltage — published value 1

    10 V

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Plate Supply Voltage — published value 2

    10 V

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Plate Supply Voltage — published value 3

    10 V

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Average Plate Current — published value 1

    10 mA

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Average Plate Current — published value 2

    10 mA

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Average Plate Current — published value 3

    10 mA

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Heater Current — published value 1

    0

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Heater Current — published value 2

    125

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Heater Current — published value 3

    0

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Heater Current — published value 4

    145

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Cathode to plate — published value 1

    2 pF

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Cathode to plate — published value 2

    0.046 pF

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • and heater — published value 1

    2 pF

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • and heater — published value 2

    5 pF

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • and heater — published value 3

    7 pF

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • and heater — published value 1

    2 pF

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • and heater — published value 2

    1.5 pF

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Heater to cathode — published value 1

    2 pF

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Heater to cathode — published value 2

    1.7 pF

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Plate Current (I) — published value 1

    1 mA

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Plate Current (I) — published value 2

    3 mA

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Plate Current (I) — published value 3

    7.8 mA

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Plate Current (I) — published value 4

    13.2 mA

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Plate Current (2) — published value 1

    2

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Plate Current (2) — published value 2

    1

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Plate Current (2) — published value 3

    4

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Plate Current (2) — published value 4

    50

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Transconductance (I) — published value 1

    1

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Transconductance (I) — published value 2

    3

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Transconductance (I) — published value 3

    10000

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Transconductance (I) — published value 4

    14800

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Transconductance (2 — published value 1

    2

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Transconductance (2 — published value 2

    3

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Transconductance (2 — published value 3

    5

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Transconductance (2 — published value 4

    8700

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Reverse Grid Current — published value 1

    6

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Reverse Grid Current — published value 2

    0

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Reverse Grid Current — published value 3

    1

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Current — published value 1

    1

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Current — published value 2

    7

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • Current — published value 3

    5

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • current issue of EIA Standard RS-191,

    191

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • (1) with the addition of a plate-load resistor of 2000 ohms — published value 1

    1 ohm

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • (1) with the addition of a plate-load resistor of 2000 ohms — published value 2

    2000 ohm

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • tube must not show an output voltage in excess of: (1) 35 — published value 1

    1 V

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • tube must not show an output voltage in excess of: (1) 35 — published value 2

    35 V

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • = 7.5 cycled one minute on end two minutes off; heater 100 — published value 1

    7.5

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • = 7.5 cycled one minute on end two minutes off; heater 100 — published value 2

    100

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • dissipation and with a metal-shell temperature of 150 °C; then

    150

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • (ac or dc) = 6. 3, plate volts = 300 negative with respect to — published value 1

    6 V

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • (ac or dc) = 6. 3, plate volts = 300 negative with respect to — published value 2

    3 V

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • (ac or dc) = 6. 3, plate volts = 300 negative with respect to — published value 3

    300 V

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • (ac or dc) = 6. 3, grid volts = 100 negative with respect to — published value 1

    6 V

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • (ac or dc) = 6. 3, grid volts = 100 negative with respect to — published value 2

    3 V

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

  • (ac or dc) = 6. 3, grid volts = 100 negative with respect to — published value 3

    100 V

    Published datasheet value; multiple numbers on a source row represent separate limits or operating conditions.

Other

  • tubes are operated for 1000 hours at maximum-rated plate

    1000 mA