Data set 01
1971 Machlette Laboratories
Published operating points and test conditions from this source.
Triode
Capacitance
Grid-Plate Capacitance
30 pF
Grid-Filament Capacitance
80 pF
Plate-Filament Capacitance
0.8 pF
Other
Filament Starting Current
800 A
Peak Plate Voltage
125000 V
Pulse
DC Grid Voltage
-1500 V
Pulse Cathode Current
175 A
Pulse
Pulse Duration
1000 us
Duty Factor
0.01