Data set 01
1938 RCA Transmitting Tubes
Published operating points and test conditions from this source.
Triode
Other
provides for operation at full rating at frequencies as high as
60 MHz
provides for operation at full rating at frequencies as high as 60 megacycles.
D-C Plate Voltage
600 V
D-C Plate Voltage ... 600 max. Volts
Plate Dissipation
20 W
Plate Dissipation .... 20 max. Watts
D-C Plate Voltage.. 425 500
600 V
D-C Plate Voltage.. 425 500 600 Volts
D-C Plate Current ... 18 24
30 mA
D-C Plate Current ... 18 24 30 Milliamperes
D-C Plate Voltage --- 400 500
600 V
D-C Plate Voltage --- 400 500 600 Volts
Peak A-F Grid-to-Grid Voltage .. 270 290
320 V
Peak A-F Grid-to-Grid Voltage .. 270 290 320 Volts
Load Resistance (Per tube) .. 1500 2000
2500 Ω
Load Resistance (Per tube) .. 1500 2000 2500 Ohms
Effective Load Res. (Plate-to-plate).- 6000 8000
10000 Ω
Effective Load Res. (Plate-to-plate).- 6000 8000 10000 Ohms
Max.-Sig. Driving Power (Approx.) 3 3
3 W
Max.-Sig. Driving Power (Approx.) 3 3 3 Watts
Max.- Sig. Power Output (Approx.) 27 36
45 W
Max.- Sig. Power Output (Approx.) 27 36 45 Watts
D-C Plate Voltage
600 V
D-C Plate Voltage .. 600 max. Volts
D-C Plate Voltage ..... 500
600 V
D-C Plate Voltage ..... 500 600 Volts
D-C Plate Current .... 45
45 mA
D-C Plate Current .... 45 45 Milliamperes
D-C Plate Current
60 mA
D-C Plate Current. 60 max. Milliamperes
D'C Plate Voltage ....... 400
500 V
D'C Plate Voltage ....... 400 500 Volts
D'O Plate Current . 55
55 mA
D'O Plate Current . 55 55 Milliamperes
Driving Power (Approx ) .. 4
4.5 W
Driving Power (Approx ) .. 4 4.5 Watts
Power Output (Approx.) . 14
18 W
Power Output (Approx.) . 14 18 Watts
D-C Grid Current
15 mA
D-C Grid Current.. 15 max. Milliamperes
D-C Grid Current (Approx.) - 15
15 mA
D-C Grid Current (Approx.) - 15 15 Milliamperes
each stated value of grid voltage should be decreased by
5 V
each stated value of grid voltage should be decreased by 5 volts and the circuit returns made to the
should not exceed
100 Ω
should not exceed 100,000 ohms.
For high-frequency operation above
60 MHz
For high-frequency operation above 60 megacycles, see page 144.