Data set 01
1937 Raytheon Radio Receiving Tubes
Published operating points and test conditions from this source.
Rectifier
Other
RMS AC voltage per plate maximum
350 V
CondenserInputFilter
Peak inverse voltage maximum
1000 V
CondenserInputFilter
Peak current per plate maximum
400 mA
CondenserInputFilter
DC output current maximum
125 mA
CondenserInputFilter
RMS AC voltage per plate maximum
400 V
CondenserInputFilter
Peak inverse voltage maximum
1100 V
CondenserInputFilter
Peak current per plate maximum
360 mA
CondenserInputFilter
DC output current maximum
110 mA
CondenserInputFilter
RMS AC voltage per plate maximum
550 V
ChokeInputFilter;20HMinimum
Peak inverse voltage maximum
1500 V
ChokeInputFilter;20HMinimum
Peak current per plate maximum
300 mA
ChokeInputFilter;20HMinimum
DC output current maximum
135 mA
ChokeInputFilter;20HMinimum
Characteristic
Average tube voltage drop
60 V
At135mADC