Miniature cold-cathode tube designed specifically to provide a highly stable approximately 83.75 V precision reference.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
-

Description

The Mullard 7980 is a miniature cold-cathode reference tube intended to provide a highly stable reference voltage.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
-
Nominal heater current
-
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Voltage Regulator

X-ray radiationInterelectrode capacitances
Regulator voltage
83.75 V
Regulator minimum current
3.5 mA
Regulator maximum current
6 mA
Regulator starting voltage
130 V
Regulator maintaining voltage
83.75 V

Cold-cathode reference discharge.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1963 Mullard

Published operating points and test conditions from this source.

SECTION 1

Voltage Regulator

Other

  • Minimum DC Starting Voltage

    130 V

  • Maximum Starting Current

    10 mA

  • Maximum Cathode Current

    6 mA

  • Minimum Cathode Current

    3.5 mA

  • Preferred Cathode Current

    4.5 mA

  • Maximum Negative Anode Voltage

    50 V

Characteristics

  • Operating Voltage Minimum

    83 V

    AtPreferredCurrent

  • Operating Voltage Maximum

    84.5 V

    AtPreferredCurrent

  • Maximum Incremental Resistance

    350 ohm

  • Minimum Incremental Resistance

    110 ohm

  • Typical RMS Noise Voltage

    100 uV

    30Hz-10kHz