Data set 01
1950 General Electric Transmitting Types
Published operating points and test conditions from this source.
MicrowaveTRSwitch
Characteristic
Main-gap operating voltage minimum
2 kV
Published datasheet value
Main-gap operating voltage maximum
2.6 kV
Published datasheet value
Trigger firing voltage minimum
5000 V
Published datasheet value
Other
Hold-off voltage indefinite
3 kV
Published datasheet value
Peak ringing current maximum
1500 A
Pulse
Peak unidirectional current maximum
4000 A
Pulse
Pulse duration maximum
10 us
Pulse