Data set 01
1961 Tung Sol
Published operating points and test conditions from this source.
Triode
Capacitance
Input Capacitance
6.5 pF
Output Capacitance
1 pF
Grid To Plate Capacitance
5.5 pF
Power - Triode Single (under 10W) ·Triode
High-perveance triode with series/parallel heater capability for general electronic service.
The 7719 is a single indirectly heated high-perveance triode intended for high-current service and equipped with a heater that can be connected for 6.3 or 12.6 volt operation.
Small-button Noval 9-contact
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
Published ratings and characteristics mapped semantically; identical repeated sections compressed.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Input Capacitance
6.5 pF
Output Capacitance
1 pF
Grid To Plate Capacitance
5.5 pF
Data set 02
Published operating points and test conditions from this source.
Heater Voltage (Series)
0.6 VOLTS
PublishedTable
Heater
310.3 VOLTS
PublishedTable
Heater
0.6 VOLTS
PublishedTable
Heater Current
0.2 AMP
PublishedTable
Plate
3 VOLTS
PublishedTable
Grid Voltage
10.5 VOLTS
PublishedTable
Plate Current
4 MA
PublishedTable
Plate Resistance
7100 OHMS
PublishedTable
Grid
15 VOLTS
PublishedTable
Maximum Plate
33 VOLTS
PublishedTable
Maximum Plate Dissipation
6 WATTS
PublishedTable
Maximum Dc Cathode Current
4 MA
PublishedTable