Data set 01
1945 Litton Industries
Published operating points and test conditions from this source.
Other
Characteristic
Frequency Range
5400 to 5900 MHz
Noise Output
13 dB
Nominal
Other
Maximum VSWR
- to 1.15
Unfired
Maximum Insertion Loss
- to 0.2 dB
Unfired
RF Power Average Maximum
- to 50 mW
Continuous operation
RF Power Peak Maximum
- to 33 W
Continuous operation
Starting Voltage Maximum
- to 700 V
DC
Operating Voltage Maximum
- to 60 V
DC
Operating Current Maximum
- to 150 mA
DC
Life
5000 to - h
50 us energized every 3000 us
Ionization Time Maximum
- to 1 us
Deionization Time Maximum
- to 20 us
Operating Ambient Temperature
-54 to 60 C