Data set 01
1971 RCA HB3 Binder 6 of 7
Published operating points and test conditions from this source.
Beam Power
Other
Maximum DC Plate Voltage
5000 V
Pulsed RF power service
Maximum DC Screen Voltage
1200 V
Pulsed RF power service
Maximum DC Plate Current During Pulse
9 A
Pulsed RF power service
Average Plate Dissipation
600 W
Pulsed RF power service
Peak Positive-Pulse Plate Voltage
10000 V
Pulsed RF power service
Typical DC Plate Voltage
4000 V
Pulsed RF power service
Typical Peak Useful Power Output
209 kW
Pulsed RF power service
Characteristics
Mu Factor, Screen to Control Grid
13