Data set 01
1971 RCA HB3 Binder 2 of 7
Published operating points and test conditions from this source.
Thyratron
Other
Filament voltage
2.5 V
Nominal
Filament current
21 A
Nominal
Maximum deionization time
1000 us
Maximum critical grid current
10 uA
Peak forward anode voltage
1500 V
Peak inverse anode voltage
1500 V
Peak negative grid voltage before conduction
500 V
Peak negative grid voltage during conduction
10 V
Peak anode/cathode current
77 A
Average anode/cathode current
6.4 A
Fault current
770 A
Short-duration fault rating
Ambient or condensed-mercury operating temperature range
-40 to +80 condensed-mercury operating range C
Characteristic
Minimum heating time prior to tube conduction
60 s
Ionization time
10 us
Approximate
Anode voltage drop
12 V
Capacitance
Grid-to-anode capacitance
4 pF
Approximate