Data set 01
1961 Tung Sol
Published operating points and test conditions from this source.
Thyratron
Other
Peak Cathode Current
800 A
Crowbar
ForwardAnodeVoltage
25 kV
Crowbar
Characteristic
Cathode Heating Time
3 min
Specialized - Thyratron ·Thyratron
Zero-bias hydrogen thyratron for very-high-peak-current crowbar protection with fast switching and recovery.
Zero-bias hydrogen thyratron for crowbar protective circuits, designed for very high peak current and fast recovery.
Small-button Noval 9-contact
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
Published ratings and characteristics mapped semantically; identical repeated sections compressed.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Peak Cathode Current
800 A
Crowbar
ForwardAnodeVoltage
25 kV
Crowbar
Cathode Heating Time
3 min