Skip to main content

Voltage Regulator ·VoltageRegulator

7475

Cold-cathode gas-discharge voltage regulator for heaterless shunt stabilization or reference service in electronic power supplies.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
A25.5-XIX
Socket code
B4
Base pins
-
Nominal heater
-

Description

The Mullard 7475 is a neon-filled voltage-stabilising tube with a 90-110 V burning range.

Socket description

European 4-pin base

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
A25.5-XIX
Socket code
B4
Base pins
-
Nominal heater voltage
-
Nominal heater current
-
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

A25.5-XIX - Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Voltage Regulator

X-ray radiationInterelectrode capacitances
Regulator voltage
95 V
Regulator minimum current
1 mA
Regulator maximum current
8 mA
Regulator starting voltage
140 V
Regulator maintaining voltage
95 V
Regulator dynamic impedance
300 Ω

Cold-cathode gas-filled Philips voltage stabilizer/reference tube.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1938 Philips Miniwatt Vacuum Tube Catalog

Published operating points and test conditions from this source.

SECTION 1

Voltage Regulator

Characteristic

  • Running voltage minimum

    90 V

    VoltageRegulator

  • Running voltage maximum

    110 V

    VoltageRegulator

  • Striking voltage minimum

    100 V

    VoltageRegulator

  • Striking voltage maximum

    135 V

    VoltageRegulator

  • Extinction voltage minimum

    85 V

    VoltageRegulator

  • Extinction voltage maximum

    110 V

    VoltageRegulator

  • Lower stabilization current

    1 mA

    VoltageRegulator

  • AC resistance

    300 Ω

    VoltageRegulator

Other

  • Quiescent current

    4 mA

    VoltageRegulator

  • Maximum permissible current

    8 mA

    VoltageRegulator

Data set 02

1951 Mullard Valve and Service Manual

Published operating points and test conditions from this source.

SECTION 1

Voltage Regulator

Characteristics

  • Burning Voltage Minimum

    90 V

  • Burning Voltage Maximum

    110 V

Other

  • Quiescent Current

    4 mA

Data set 03

1957 Philips Receiving and Amplifying Tubes

Published operating points and test conditions from this source.

SECTION 1

Voltage Regulator

Characteristics

  • Maintaining/Reference Voltage

    95 V

Other

  • Minimum Current

    1 mA

  • Maximum Current

    8 mA

  • Ignition Voltage Maximum

    140 V

Data set 04

1963 Philips Electron Tubes Handbook V2

Published operating points and test conditions from this source.

SECTION 1

Voltage Regulator

Characteristic

  • Maintaining voltage at 4 mA

    95 V

  • Voltage regulation

    - to 8 V

    Ia=1-8mA

Data set 05

1999 Philips 0-D

Published operating points and test conditions from this source.

SECTION 1

Voltage Regulator

Characteristics

  • Operating voltage

    100 V

  • Voltage at 4 mA

    95 V

  • Regulation maximum

    8 V

    Ia1to8mA

  • Va (Ia ma)

    212 ma

    PublishedLine: Va (Ia=¢ ma) 212 95 7

  • Vo (Ia

    4 mA

    PublishedLine: Vo (Ia=4 mA) = 95 Ve

Other

  • Starting voltage maximum

    140 V

  • Anode current minimum

    1 mA

  • Anode current maximum

    8 mA

  • Courant moyen max.

    4 mA

    PublishedLine: Courant moyen max. &4 mA

  • Ia max

    8 mA

    PublishedLine: Ia = max. 8 mA

  • Ig min

    1 mA

    PublishedLine: Ig min. 1 mA

  • Ia maX

    8 mA

    PublishedLine: Ia = maX,. 8 mA

  • Ia min

    1 mA

    PublishedLine: Ia min. 1 mA