Data set 01
1938 Raytheon
Published operating points and test conditions from this source.
Magnetron
Other
delivering a peak power output of 60 to
120 W
delivering a peak power output of 60 to 120 watts. It is capable of being
tuned to any frequency within the 9300 to
9500 MHz
tuned to any frequency within the 9300 to 9500 Mc range.
Heater Voltage — Preheat and Operate . 5.0 to
5.5 V
Heater Voltage — Preheat and Operate . 5.0 to 5.5 volts
Heater Current
650 mA
Heater Current . 0.65 Ampere at 5.0 Volts
at 15G, 20 to
2000 Hz
at 15G, 20 to 2000 cps . . 3.0/tp Mc, Max. Bandwidth
Pulse Duration . . 0.35 to
1 µs
Pulse Duration . . 0.35 to 1.0 Microseconds
Peak Anode Current
950 mA
Peak Anode Current . . 0.95 Amperes
Peak Anode Voltage 1.35 to
1.55 kV
Peak Anode Voltage 1.35 to 1.55 Kilovolts
Peak Power Output . . 60 to
120 W
Peak Power Output . . 60 to 120 Watts