Data set 01
1971 Machlette Laboratories
Published operating points and test conditions from this source.
Triode
Capacitance
Grid-Plate Capacitance
5 pF
Grid-Cathode Capacitance
250 pF
Plate-Cathode Capacitance
50 pF
Other
Peak Plate Voltage
25000 V
Pulse
DC Grid Voltage
-300 V
Peak Positive Grid Voltage
1000 V
Peak Negative Grid Voltage
-1000 V
DC Plate Current
200 mA
Pulse Duration
25 us
Duty Factor
0.03