Data set 01
1971 RCA HB3 Binder 2 of 7
Published operating points and test conditions from this source.
Thyratron
Other
Filament voltage
2.5 V
Nominal
Filament current
5 A
Nominal
Maximum deionization time
1000 us
Maximum critical grid current
5 uA
Peak forward anode voltage
1250 V
Peak inverse anode voltage
1250 V
Peak negative grid voltage before conduction
500 V
Peak negative grid voltage during conduction
10 V
Peak anode/cathode current
3 A
Average anode/cathode current
1 A
Fault current
50 A
Short-duration fault rating
Ambient or condensed-mercury operating temperature range
+40 to +80 condensed-mercury operating range C
Characteristic
Minimum heating time prior to tube conduction
5 s
Ionization time
10 us
Approximate
Anode voltage drop
15 V
Capacitance
Grid-to-anode capacitance
2 pF
Approximate