Data set 01
1953 Amperex
Published operating points and test conditions from this source.
Rectifier
Other
Heater/Filament Voltage
5 V
Heater/Filament Current
11.5 A
Maximum Peak Inverse Voltage
15000 V
Rectifier - Half Wave ·Rectifier
Convection-cooled directly heated mercury-vapor half-wave rectifier for industrial supplies. Rated for approximately 15 kV peak inverse voltage, 2.5 A DC output, and 12 A peak current.
7136 is listed in the supplied Amperex material as a convection-cooled mercury-vapor half-wave rectifier. Published electrical ratings and operating data were captured from the supplied table.
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
Published maximum ratings and general characteristics promoted from the supplied datasheet.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Heater/Filament Voltage
5 V
Heater/Filament Current
11.5 A
Maximum Peak Inverse Voltage
15000 V
Data set 02
Published operating points and test conditions from this source.
Heater/filament voltage
5 V
Published rating
Heater/filament current
11.5 A
Published rating
Filament heating time
60 s
MercuryVapor HalfWave
Tube voltage drop
12 V
MercuryVapor HalfWave
Operating temperature minimum
15 C
MercuryVapor
Operating temperature maximum
35 C
MercuryVapor
Maximum peak inverse voltage
15000 V
MercuryVapor HalfWave
Maximum DC output current
2.5 A
MercuryVapor HalfWave
Maximum peak plate current
12 A
MercuryVapor HalfWave