Power - Triode (over 1000V 100W) ·Triode
7124
Water-cooled high-power Class-AB1 linear-amplifier triode with 40-kW maximum plate dissipation.
Directly heatedCold cathodeCommon cathodeDissimilar
- Sections
- 1
- Base
- -
- Socket code
- -
- Base pins
- -
- Nominal heater
- 8 V / 200 A
Description
Water-cooled high-power Class-AB1 triode.
General specifications
Tube and section characteristics
Properties common to every published source and operating point.
Heater and base
- Base
- -
- Socket code
- -
- Base pins
- -
- Nominal heater voltage
- 8 V
- Nominal heater current
- 200 A
- Parallel heater voltage
- -
- Parallel heater current
- -
- Series capable
- No
Terminal pinout
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
Section ratings
1 physical section, each with unique specifications.
Section 1
Triode
X-ray radiationInterelectrode capacitances
- Amplification factor
- 4.5
- Max plate voltage
- 12500 V
- Max plate dissipation
- 40000 W
- Max cathode current
- 8 A
Source-dependent data
Operating conditions by source
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.